IVM200AS Aramid FR Viscose Inherent Flame Retardant Fabric

  • Item Code: IVM200AS
  • Fabric Weight: 200GSM
  • Composition: 49%FR viscose 49% meta aramid, 2% anti-static,
  • Useable Width: 57‘’58‘’
  • Weave: 2/1twill
  • Function: Flame retardant and arc resistant
  • Product description
  • Parameter
  • IVM200AS Aramid FR Viscose Inherent Flame Retardant Fabric

    Fabric description and key features

    For many industrial workers, heavy protective clothing brings obvious stuffiness and heat stress during long shifts.
     

    IVM200AS solves this pain point perfectly. It is an inherent flame retardant twill fabric blended with meta-aramid and FR viscose plus embedded anti-static conductive fiber.

     

    Flame resistance is built into fiber molecular structure, never washed away. It balances reliable thermal hazard protection and superior wearing comfort, becoming a cost-effective mainstream material for mid-range FR protective uniforms worldwide.


    1. Dual Inherent Fibre System – Permanent FR Performance

    Both meta-aramid and FR viscose are inherently flame resistant, not surface chemical finishing.

     

    When exposed to flame, the fabric quickly carbonises to form a thermal insulation barrier.

     

    ✅ Protection remains stable after repeated industrial laundering

     

    ✅ No melting & no drip, avoid secondary burn injuries

     

    ✅ No gradual decay of flame retardancy compared with coated FR cotton

     

    2. FR Viscose Delivers Outstanding Wear Comfort

    This is the biggest difference between IVM200AS and full aramid fabric (like AM210).
    • FR viscose possesses excellent moisture absorption & breathability, effectively dissipating sweat
    • Softer hand feel, better drape, less rigid than pure aramid
    • Greatly reduces heat stress for staff working in hot environments
    • Improved wearing experience enhances workers’ willingness to wear PPE

     

    3. Built-in Permanent Anti-Static Function

    Continuous anti-static conductive filament evenly distributed in yarn structure.

     

    Effectively release static charge, prevent electrostatic spark ignition risks, suitable for flammable & explosive working environments such as oil & gas, chemical plants.

     

    4. Balanced Cost & Safety Performance

    Compared with high-content para-aramid fabrics, IVM200AS offers a competitive price level while meeting international FR safety standards.

     

    5. Good Fabric Stability

    • Low shrinkage after industrial washing
    • Satisfactory colour fastness, anti-pilling property
    • Flexible twill structure, suitable for tailored coveralls, jackets and trousers

     

    Typical Application Scenarios

    Protective garments made of IVM200AS are widely used across multiple industries:
    • Oil & gas, petrochemical, chemical processing FR coveralls
    • Power station, substation auxiliary arc-flash workwear
    • General metallurgy, machinery welding protective uniforms
    • Mining, hazardous chemical factory anti-static flame resistant workwear
    • Logistics, energy engineering site safety uniforms
    Color Runs

    OEM Service,Customized Color per Buyer Requirement

    Meet Standards

     9oz flame retardant fabric   9oz flame retardant fabric   9oz flame retardant fabric   9oz flame retardant fabric

     

    EN11611: Protective clothing for use in welding and allied processes.

    EN11612: Protective clothing. Clothing to protect against heat and flame.

    EN61482-1-2 Box test Class 1: Live Working - Protective Clothing against the thermal hazards of an electric arc.

    NFPA 2112: Flame resistant garments for protection of industrial personnel against flash fire.

    Related Products

    Inherent FR Fabric Series

    AM150-P Aramid Fabric

    93% meta aramid 5% para aramid 2% anti-static,

    plain, 150gsm

    Flame Retardant: EN 11611; EN 11612; NFPA 2112

    Antistatic:EN 1149

    AM210Aramid IIIA fabric  

    93% meta aramid 5% para aramid  2% anti-static, 2/1

    twill, 210gsm

    Flame Retardant: EN 11611; EN 11612; NFPA 2112; EN 469

    Antistatic:EN 1149

    Electric Arc: EN 61482-1-1; EN 61482-1-2

    IVM200AS

    49%FR viscose 49% meta aramid, 2% anti-static, 

    2/1 twill, 200gsm

    Flame Retardant: EN 11611; EN 11612; NFPA 2112

    Electric Arc: EN 61482-1-1; EN 61482-1-2

    IVM120

     

    50%FR viscose 50%meta aramid, 1/1 plain, 120gsm

    Flame Retardant: EN 11611; EN 11612; NFPA  2112
    IMC270

    55%modacrylic 43%cotton 2%anti-static,

    2/1 twill, 270gsm

    Flame Retardant: EN 11611; EN 11612

    Antistatic: EN 1149

    Hi-Vis: EN 20471

    Electric Arc: EN 61482-1-2

    MTA250AS

    48% Modacrylic 36% Tencel,15% Para-aramid,

    1% Anti-static,twill, 250gsm

    Flame Retardant: EN 11611; EN 11612

    Antistatic: EN 1149

    Electric Arc: EN 61482-1-1; EN 61482-1-2

    MCA240AS

    Modacrylic Cotton Para aramid Anti-static ,

    2/1 twill, 240gsm

    Flame Retardant: EN 11611; EN 11612

    Antistatic:EN 1149

     